The Model SPP self-priming sewage pump is a new-generation product developed through the introduction of advanced American technology and manufacturing processes. Designed to overcome the inherent drawbacks of traditional self-priming pumps, it features an innovative structure, reliable performance, and an original battleship-style appearance—a first in China. Equipped with an oil-lubricated mechanical seal, a non-clog open impeller, a replaceable wear plate, and an advanced shredding device, this series sets a new standard for solid handling.
The SPP series includes 7 sizes ranging from 2 inches to 12 inches, delivering a performance range of 10 to 1,500 m³/h in capacity and 10 to 68 meters in head. Custom requirements can easily be met by trimming the outer impeller diameter, adjusting rotational speed, or combining different models. Built with a grey cast iron casing and a ductile iron impeller, the pump is widely used in municipal sewage, industrial wastewater treatment, and centralized systems handling liquids with high solid content or mild corrosion.
Fully optimized for harsh sewage conditions, the pump includes a quick-cleaning front access port to clear blockages rapidly. The distinctive oil-lubricated seal chamber provides superior reliability and protects against dry-running damage. Key components, such as thrust bearings are SKF equipped to guarantee stable, low-noise operation and a service life of over 20 years. It effectively resolves the common weaknesses of conventional submersible pumps—such as poor solids passage, complex installation, difficult maintenance, and frequent breakdowns.
| Model | Size, in (mm) | Speed, rpm | Max flow, m³/h | Max head, m | Motor, HP | Max solid, mm | Weight, kg |
|---|---|---|---|---|---|---|---|
| SPP-2 | 2" × 2" (50 × 50) | 1150–2900 | 46 | 35 | 1–10 | 44.45 | 92 |
| SPP-3 | 3" × 3" (75 × 75) | 650–2150 | 107 | 35 | 1–20 | 63.5 | 183 |
| SPP-4 | 4" × 4" (100 × 100) | 650–1950 | 163 | 36 | 1–30 | 76.2 | 259.5 |
| SPP-6 | 6" × 6" (150 × 150) | 650–1550 | 330 | 33 | 2–40 | 76.2 | 364 |
| SPP-8 | 8" × 8" (200 × 200) | 650–1350 | 600 | 34 | 7.5–75 | 76.2 | 581 |
| SPP-10 | 10" × 10" (250 × 250) | 650–1450 | 775 | 40 | 10–100 | 76.2 | 635 |
| SPP-12 | 12" × 10" (300 × 250) | 650–1250 | 1,275 | 42 | 20–125 | 76.2 | 998 |
Source: SPP operating range table, catalogue 2026.10. Series headline figures in the brochure are rounded; the per-model values above are the ones to select from. Maximum flow and maximum head are not simultaneous — confirm the duty point on the issued curve. Motor figures are the catalogue HP range; 1 HP = 0.746 kW.
| Part | Standard | Option |
|---|---|---|
| Casing | HT200 | SS 304/316/316L |
| Impeller | QT450-10 | SS 304/316/316L |
| Wear plate | Q235A | Stainless |
| Shaft | 40Cr | — |
| Seal | Cartridge, WC/WC | — |
| Bearing | SKF thrust | — |
Example: SPP-2 M-Q-A-F is a 2-inch pump with ductile iron impeller, cast iron casing, DIN flange and motor drive. Stainless builds replace the material positions with S.
The order of these steps is not arbitrary. A model that satisfies the flow but cannot prime from your lift is not a cheaper option — it is a pump that will run dry. Work down the list and stop when a constraint fails.
Sewage arrives unevenly. Take the design inflow, apply the peak factor your authority requires, and size the pump to pass that peak with the sump level still falling. A pump chosen on average flow will cycle too often and spend its life away from its best point.
Output: design flow, m³/hStatic lift from sump floor to discharge outlet, friction in suction and discharge at the design flow, velocity head, and any pressure the discharge must overcome. Use the pipe's internal diameter after fouling, not the nominal size. A 10% underestimate in friction moves the duty point further than a change of impeller trim.
Output: total head at design flow, m44.45 mm on SPP-2, 63.5 mm on SPP-3, 76.2 mm from SPP-4 upward. If the upstream screen passes 80 mm solids, no SPP size will pass them either — the screen is the fix, not a larger pump.
Output: model floor set by passage sizeSelf-priming height depends on speed. SPP-12 lifts 1.6 m at 650 rpm and 4.9 m at its 1,250 rpm maximum. SPP-2 reaches 7.6 m from 1,450 rpm. A large casing idling at low speed will not lift 6 m, whatever the series headline says.
Output: usable speed band, and a model shortlistRead shaft power at the duty point, multiply by the density ratio (1.3 at 1,300 kg/m³), and size the motor above that figure — not above the power at best efficiency. Check the maximum-flow end of the curve as well: power rises towards free delivery on most of these curves.
Output: motor kW, and the overload caseMaximum flow and maximum head are separate points on each envelope; no model delivers both at once. Use this to shortlist a casing, then read the real curve at your duty point.
| Duty flow | Model | Max solid | Priming at top speed |
|---|---|---|---|
| up to 46 m³/h | SPP-2 | 44.45 mm | 7.6 m at 2,900 rpm |
| 46–107 m³/h | SPP-3 | 63.5 mm | 7.6 m at 2,150 rpm |
| 107–163 m³/h | SPP-4 | 76.2 mm | 7.6 m at 1,950 rpm |
| 163–330 m³/h | SPP-6 | 76.2 mm | 7.6 m at 1,550 rpm |
| 330–600 m³/h | SPP-8 | 76.2 mm | 7.0 m at 1,350 rpm |
| 600–775 m³/h | SPP-10 | 76.2 mm | 6.7 m at 1,450 rpm |
| 775–1,275 m³/h | SPP-12 | 76.2 mm | 4.9 m at 1,250 rpm |
This table answers one question only: which casing is large enough for the flow. A model whose maximum flow is above the duty can still be the wrong choice on head, suction lift or solids — read the curve before ordering. Where a duty sits near a band edge, screen both models.
The example is SPP-2, the smallest casing, drawn from 1,150 to 2,900 rpm. The other six models use the same layout with different numbers, so the reading method transfers unchanged.
2,900 / 2,650 / 2,350 / 2,050 / 1,750 / 1,450 / 1,150 rpm. Each bold line is a complete head-flow curve at that speed. Between two lines the affinity laws apply, which is how a pulley change moves the duty point without touching the impeller.
20% to 48%, drawn as a family across the map. Select as close to the inner island as the duty allows. Far to the right of it, kilowatts and recirculation wear rise; far to the left, flow becomes unstable and the casing heats up.
1 / 1.5 / 2 / 3 / 5 / 7.5 / 10 HP at 2,900 rpm. Read power where the duty point lands, then apply the density ratio and the motor margin. Note the direction: power rises towards free delivery, so the right-hand end of the curve — not the middle — is the overload case.
6.6 to 32.8 ft at 2,900 rpm, rising with flow. Available NPSH has to stay above this line with a margin of 0.5–1.0 m. On a suction-lift installation the available figure is small, so this line — not the head curve — decides how far the pump can draw.
The dashed boundary defines the recommended continuous duty zone. Left of it, recirculation raises casing temperature; right of it, cavitation and motor overload begin. A duty point outside the boundary is a wrong selection, not a trimming problem.
The series is quoted at 7.6 m, but that figure belongs to the small casings at high speed. Each model primes less at low speed, and the largest casing primes least of all. Plot the seven tables together and the constraint becomes visible before any flow calculation.
Catalogue priming heights, 0–7.6 m. Actual lift also depends on suction-pipe friction, liquid temperature and air leakage; values are measured on a flooded casing with a clean suction line.
Read across at your lift. A 6 m lift is available on SPP-2 from 1,450 rpm, on SPP-4 from 1,050 rpm, on SPP-6 and SPP-8 from 1,150 rpm, and on SPP-10 only from 1,350 rpm. It is not available at all on SPP-12, whose best is 4.9 m at 1,250 rpm — the casing is simply too large to pull that column of water at the speeds it can run.
For a fixed impeller, speed is the only free variable. The three affinity relations below hold for the trimmed speed range of these casings; outside roughly ±20% of the design speed, efficiency and NPSH should be re-read from the curve rather than extrapolated.
Example: SPP-6 at 1,450 rpm reduced to 1,250 rpm — 86% speed gives 86% flow, 74% head and 64% shaft power. That is why a belt change is often enough to bring an oversized pump back onto its curve.